MPM Econergy


The MPM ECONERGY boiler is a modular device.   Depending on the customer's preference, he or she can choose a boiler with a built-in cylinder or a cylinder freely located in relation to the exchanger. In the case of the built-in cylinder, the compact design means that the appliance can fit into even very small rooms. On the other hand, in the second option, the free-standing cylinder is larger, an excellent choice for those who have a large space in the boiler room and will additionally enjoy the boiler's prolonged fixed combustion. The boiler is certified as Class 5 and ecodesign by the Brno Institute.

General information

Compact design

Automatic pellet boilers usually take up a lot of space due to the charging hoppers located next to the boiler. In the MPM Econergy ecoTouch 860 boiler, the charging hopper is located above the exchanger. Thanks to its compact design, this boiler is ideal for small spaces. 

 

Safety at the highest level 

The safety of the user is one of our company's primary concerns when designing the boiler. The boiler door is equipped with a system of sensors, which prevents the user from coming into contact with the flame and from possible burns. The boiler burner is equipped with safeguards preventing fuel supply during overheating of the system or flame failure. Additionally, the ecoTouch 860 controller can be fitted with modules which also positively affect user comfort and safety.

 

High level of care for the environment

By using renewable heat sources such as pellets, we are making a contribution to environmental protection. Pellets are made from residues not used in the processing of wood, while in the combustion process they do not produce harmful tarry substances - we emit less CO2 when heating our home.

 

MPM Econergy boilers are available in capacities of 10 kW, 15 kW, 20 kW, 25 kW, 30 kW.

 

Take care of the additional equipment of your boiler:

  • MPM 55 anti-condensation system - 7-year warranty 
  • Anti-condensation valve 
  • EVOSTA pump

technical data

Parameter

Unit

Value

 Nominal heat output

kW

10

15

20

25

30

 Heat output range

kW

3-10

4,5-15

6-20

7,2-25

8,4-28

 Required exhaust line

mbar

MINIMUM 0,15

 Boiler water volume

l.

35,5

50

66

 Exhaust gas temperature (nominal output)

⁰C

81,1

89,4

97,7

110,1

117,6

 Exhaust gas temperature (minimum power)

⁰C

59,4

64,3

69,2

69,3

69,4

 Water flow resistance (nominal output)

mbar

0,08

0,25

0,3

 Water flow resistance (minimum power)

mbar

0,04

0,01

0,08

 Boiler class (according to EN 303 -5: 2021-09) 

-

5

 Sustainability (nominal output)

h

54

34

36

27

35,5

 Sustainability (minimum power)

h

172,5

111

111,5

91

110,5

 Setting range of temp. controller

⁰C

50-85

 Min. water temp. in boiler feed port (d)

⁰C

45

 Auxiliary power required (nominal power)

W

61

65,5

70

79,4

85

 Auxiliary power required (minimum power)

W

50

47,5

45

49,4

52

 Auxiliary power required (stand-by)

W

3

 Required cold water temperature

⁰C

45

 Required feed water pressure

bar

min 3

MPM Econergy

The MPM ECONERGY boiler is a modular device.   Depending on the customer's preference, he or she can choose a boiler with a built-in cylinder or a cylinder freely located in relation to the exchanger. In the case of the built-in cylinder, the compact design means that the appliance can fit into even very small rooms. On the other hand, in the second option, the free-standing cylinder is larger, an excellent choice for those who have a large space in the boiler room and will additionally enjoy the boiler's prolonged fixed combustion. The boiler is certified as Class 5 and ecodesign by the Brno Institute.

General information

Compact design

Automatic pellet boilers usually take up a lot of space due to the charging hoppers located next to the boiler. In the MPM Econergy ecoTouch 860 boiler, the charging hopper is located above the exchanger. Thanks to its compact design, this boiler is ideal for small spaces. 

 

Safety at the highest level 

The safety of the user is one of our company's primary concerns when designing the boiler. The boiler door is equipped with a system of sensors, which prevents the user from coming into contact with the flame and from possible burns. The boiler burner is equipped with safeguards preventing fuel supply during overheating of the system or flame failure. Additionally, the ecoTouch 860 controller can be fitted with modules which also positively affect user comfort and safety.

 

High level of care for the environment

By using renewable heat sources such as pellets, we are making a contribution to environmental protection. Pellets are made from residues not used in the processing of wood, while in the combustion process they do not produce harmful tarry substances - we emit less CO2 when heating our home.

 

MPM Econergy boilers are available in capacities of 10 kW, 15 kW, 20 kW, 25 kW, 30 kW.

 

Take care of the additional equipment of your boiler:

  • MPM 55 anti-condensation system - 7-year warranty 
  • Anti-condensation valve 
  • EVOSTA pump

technical data

Parameter

Unit

Value

 Nominal heat output

kW

10

15

20

25

30

 Heat output range

kW

3-10

4,5-15

6-20

7,2-25

8,4-28

 Required exhaust line

mbar

MINIMUM 0,15

 Boiler water volume

l.

35,5

50

66

 Exhaust gas temperature (nominal output)

⁰C

81,1

89,4

97,7

110,1

117,6

 Exhaust gas temperature (minimum power)

⁰C

59,4

64,3

69,2

69,3

69,4

 Water flow resistance (nominal output)

mbar

0,08

0,25

0,3

 Water flow resistance (minimum power)

mbar

0,04

0,01

0,08

 Boiler class (according to EN 303 -5: 2021-09) 

-

5

 Sustainability (nominal output)

h

54

34

36

27

35,5

 Sustainability (minimum power)

h

172,5

111

111,5

91

110,5

 Setting range of temp. controller

⁰C

50-85

 Min. water temp. in boiler feed port (d)

⁰C

45

 Auxiliary power required (nominal power)

W

61

65,5

70

79,4

85

 Auxiliary power required (minimum power)

W

50

47,5

45

49,4

52

 Auxiliary power required (stand-by)

W

3

 Required cold water temperature

⁰C

45

 Required feed water pressure

bar

min 3

+++++

For download